传送门: 设为首页 收藏本站

智慧城市文库

PDF

pxc 固件3.4

阅读 686 下载 0 大小 407.3K 总页数 17 页 2022-11-14 分享
下载文档
/ 17
全屏查看
pxc 固件3.4
还有 17 页未读 ,您可以 继续阅读 或 下载文档
1、本文档共计 17 页,下载后文档不带水印,支持完整阅读内容或进行编辑。
2、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
4、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。
SIEMENSFirmware Revision 3.4Release Notes沃思文档588-584-3P4Building Technologies2016-06-08Copyright NoticeCopyright NoticeNoticeDocument information is subject to change without notice by Siemens Industry,Inc.Companies,names,and various data used in examples are fictitious unless otherwisenoted.No part of this document may be reproduced or transmitted in any form or byany means,electronic or mechanical,for any purpose,without the express writtenpermission of Siemens Industry,Inc.All software described in this document is furnished under a license agreement andmay be used or copied only in accordance with license terms.For further information,contact your nearest Siemens Industry,Inc.representative.Copyright 2016 Siemens Industry,Inc.To the ReaderYour feedback is important to us.If you have comments about this manual,pleasesubmit them to:SBT_technical.editor.us.sbt@siemens.comCreditsStaefa and TALON are registered trademarks of Siemens Industry,Inc.Other product or company names mentioned herein may be the trademarks of theirrespective owners.Printed in the USA.Siemens Industry.Inc.Firmware Revision 3.4 Release Notes588.584-3P4Building Technologies2016-06-08Table of ContentsSection 1-New Features and EnhancementsTotalization for Analog and Multistate Points.5Totalized Point Report5Additional Trend Interval Rates for Time-based Trends.Deleting Multiple Points or PPCLPrograms..6FLN NetworkTwo MS/TP FLN Connections Supported...7Integration Driver Support on Field Panel Web Ul.7Slope/Intercept Calculator...........7Enhancements to Application MC......7Field Panel Editor Enhancements.....7TALON ToolsSection 3-Installation..........TALON Firmware Compatibility with TALON View Software and TALONCommissioner..........13Addendum,Revision 3.4 Build 12.65.0043........16Siemens Industry,Inc.Firmware Revision 3.4 Release Notes588-584-3P4Building Technologies2016-06-08Section 1-New Features and EnhancementsTotalization for Analog and Multistate PointsSection 1 New Features and EnhancementsTotalization for Analog and Multistate PointsThe Point Commander and Point Editor now support totalization for analog andmultistate points.The following point types may now be totalized:·LDI·L2SL·L2SP·LOOALLOOAP·LFSSL·LFSSPThe totalization function accumulates the runtime value of a point.Examples for usingthis feature include:Accumulating runtime for fans and pumps.Accumulating total volume from a flow rate sensor.Calculating degree days.NOTE:Using the PPCL TOTAL function to access the totalized value of a BACnet MultistateOutput point is currently not supported.Totalized Point ReportThe BACnet Field Panel Web Server(FPWeb)now offers a Totalized Point report,which displays the panel name,point name,totalized value,reset date and time,andreset value.To open the report,click the Totalized Point Reporticon under theReportingReportingbar.Siemens Industry,Inc.Firmware Revision 3.4 Release Notes588-584-3P4Building Technologies2016-06-08Section 1-New Features and EnhancementsAdditional Trend Interval Rates for Time-based TrendsTotalized Point Report xTotalized Point ReportPanels:Siemens...Name:ResultsPanelTotalized ValueReset Date and Time Reset ValueSiemens100.0 HoursSiemens100.0 Minutes09-01-201511:45:380.0Siemens1033877.56 kW Hours09-01-201511:46:390.0Siemens102032654 k Minutes09-01-201511:45:390.0Siemens10AV_LAO09-01-201511:45:390.0Siemens1009-01-201511:45:400.0Siemens1009-01-201511:45:400.0Siemens10bwTTLSecond (REVRSE)1219583 Seconds09-01-201511:46:400.0Siemens1009-01-201511:46:400.0Siemens1009-01-201511:46:410.0Siemens100.0 Hours09-01-201511:46:410.0Figure 1:Totalized Point Report Example.Additional Trend Interval Rates for Time-basedTrendsThe Trend Editor has been enhanced to support additional trend interval rates for time-based trends.The trend interval options for time-based trends are now hours,minutes,and seconds.Deleting Multiple Points or PPCL Programs.The BACnet Field Panel Web Client Point Editor now allows you to delete multiplepoints..The BACnet Field Panel Web Client PPCL Editor now allows you to delete multiplePPCL programs without having to open them one-by-one.FLN Network TypesMS/TP Routed and Ethernet/IP FLNs are now supported for BACnet devices.BACnet MS/TP routed FLN is supported for Programmable TECs(PTECs),UnitaryEquipment Controllers (UECs),and third-party BACnet devices.FIN Builder supports MS/TP routed FLNs and IP FLNs.PPCL and Point Editing are currently not available on routed FLNs.Auto-discovery is supported for all BACnet FLN network types.An Integration FLN is now available.For Integration Drivers that support FPWebIntegration FLNs can be viewed and modified from the FPWeb Ul and in Kiosk mode.The following products support the MS/TP Routed,Ethernet/IP,and Integration FLNs:.Application Monitoring and Control System Tool(AppMC)·FIN BuilderFINlite·Launch PadSiemens Industry,IncFirmware Revision 3.4 Release Notes588-584-3P4Building Technologies2016-06-08
文档评分
    请如实的对该文档进行评分
  • 0
发表评论
返回顶部